2. SELECTING THE INSTALLATION SITE
Indoor Unit
AVOID:
●
areas where leakage of flammable gas may be
expected.
●
places where large amounts of oil mist exist.
●
direct sunlight.
●
locations near heat sources which may affect the
performance of the unit.
●
locations where external air may enter the room
directly. This may cause “sweating” on the air
discharge ports, causing them to spray or drip.
●
Iocations where the remote controller will be
splashed with water or affected by dampness or
humidity.
●
installing the remote controller behind curtains or
furniture.
DO:
●
select an appropriate position from which every
corner of the room can be uniformly cooled.
●
select a location where the ceiling is strong enough
to support the weight of the unit.
●
select a location where tubing and drain pipe have
the shortest run to the outdoor unit.
●
allow room for operation and maintenance as well
as unrestricted air flow around the unit.
●
install the unit within the maximum elevation
difference above or below the outdoor unit and
within a total tubing length from the outdoor unit as
detailed in Table 1-10.
●
allow room for mounting the remote controller about
1m off the floor, in an area that is not in direct
sunlight nor in the flow of cool air from the indoor
unit.
NOTE
Air delivery will be degraded if the distance from the
floor to the ceiling is greater than 3 m.
Ceiling-Mounted Type
Concealed-Duct Type
2-Way, 4-Way Semi-Concealed Type
0769_T_I
min. 25 cm
Front view
The rear of the indoor unit can be installed flush
against the wall.
min. 30 cm
Air intake
Air
discharge
Side view
min. 25 cm
Ceiling
Wall
NOTE
0021_X_I
1m
1m
1m
1m
1m
Front view
Side view
1-Way Semi-Concealed Type
min. 5 cm
min. 5 cm
min. 1 m
Air
intake
Air
discharge
Obstacle
Ceiling
Wall
Wall
0770_AS_I
Side view
Floor-Standing, Concealed Floor-Standing Type
min.
10 cm
min. 100 cm
0754_M_I
min.
10 cm
min. 100 cm
Horizontal view
Vertical view
Wall-Mounted Type
min.15 cm
Front View
0771_K_I
min.
15 cm
min.
15 cm