<Outline>
Defrosting carried out by the cooling cycle (reverse cycle). The defrosting time or outdoor heat exchanger
temperature must be more than its fixed value when finishing.
<Detail>
•
Conditions for Starting Defrost
The starting condition must be made with the outdoor air temperature and heat exchanger temperature.
Under the conditions that the system is in heating operation, 6 minutes after the compressor is started and
more than 44 minutes of accumulated time pass since the start of the operation or ending the defrosting.
•
Conditions for Canceling Defrost
The judgment must be made with heat exchanger temperature.( 4 °C to 22 °C)
7-2-8. Defrost Control
<Outline>
Fan control is carried out according to the following priority.
(1) Fan ON control for electric component cooling fan
(2) Fan control when defrosting
(3)
Fan OFF delay when stopped
(4)
ON/OFF control in cooling operation
(5) Tap control when drooping function is working.
(6)
Fan control in forced operation
(7)
Fan control in indoor / outdoor unit silent operation
(8)
Fan control in powerful mode
(9) Fan control in normal operation
<Detail>
Fan OFF Control when Compressor is Stopped.
•
Fan OFF delay for 60 seconds must be made when the compressor is stopped.
Tap Control in indoor / outdoor unit silent operation
(1) Cooling Operation
When the outdoor air temperature is lower than 37 °C, the fan tap must be set to L.
(2) Heating Operation
When the outdoor air temperature is higher than 4 °C, the fan tap must be turned to L.
7-2-9. Fan Control
Fr
equency
Compressor
Four way valve
Fan
Electronic expansion
valve opening
ON
OFF
ON
OFF
ON
OFF
0Hz
5sec.
350pps
450pps
450pps
Initial opening
PI control
5sec.
50sec.
50sec.
600sec.
60sec.
32
Содержание SAP-CRV12AEH
Страница 13: ...3 DIMENSIONAL DATA Indoor Unit SAP KRV9AEH SAP KRV12AEH 770 201 283 548 5 258 5 126 5 770 283 13 ...
Страница 14: ...Outdoor Unit SAP CRV9AEH SAP CRV12AEH 708 658 275 550 317 470 299 14 ...
Страница 67: ...INSTRUCTION MANUAL SAP KRV9AEH SAP CRV9AEH SAP KRV12AEH SAP CRV12AEH OI 852 6 4181 180 00 1 APPENDIX A A 1 ...
Страница 107: ......
Страница 108: ...SANYO Electric Co Ltd Osaka Japan June 2010 Printed in Japan B ...