8-3. Troubleshooting from Error Display
Code
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
EE
EE
E2
H4
H6
F2
F1
UF
H3
LC
UH
E5
U7
U1
H7
Heating LED-pause 3 seconds
and blink 15 times
Heating LED-pause 3 seconds
and blink 15 times
Running LED-pause 3 seconds
and blink 2 times
Heating LED-pause 3 seconds
and blink 4 times
Running LED-pause 3 seconds
and blink 11 times
Cooling LED-pause 3 seconds
and blink 2 times
Cooling LED-pause 3 seconds
and blink 1 time
Heating and cooling LED blink
7 times at the same time
Heating LED-pause 3 seconds
and blink 3 times
Heating LED-pause 3 seconds
and blink 11 times
Heating and cooling LED blink
8 times at the same time
Running LED-pause 3 seconds
and blink 5 times
Cooling LED-pause 3 seconds
and blink 20 times
Heating LED-pause 3 seconds
and blink 13 times
Heating LED-pause 3 seconds
and blink 7 times
Replace indoor main board.
Replace indoor main board.
Outdoor ambient temperature is too low.
System is abnormal, check if the evaporator
and condenser is dirty and blocked.
Is electromotor mounted normally ?
Is it loose ?
Measure the resistance value with universal
meter.
Is it loose ?
Measure the resistance value with universal
meter.
Replace indoor main board.
Inspect connection state of the overload wire.
Check if the resistance of compressor and
resistance to ground is normal.
If the compressor is normal, the outdoor main
board may be wrong.
This malfunction may happen when outdoor
DC electromotor is used.
Is electric network variable ?
Replace 4-way valve.
Replace outdoor main board.
Check if the resistance of compressor and
resistance to ground is normal.
If the compressor is normal, the outdoor main
board may be wrong.
Storage slug
Indoor PCB
malfunction
Anti-freezing protection
Overload of system
No motor of indoor
unit feedback
Indoor pipe
temperature sensor
malfunction
Internal ambient
temperature sensor
malfunction
Zero passage
abnormal
Overload of
compressor
Startup failure
No motor of outdoor
unit feedback
Over current
protection
4-way valve
conversion abnormal
Phase current
detection malfunction
of compressor
Sync failure
Malfunction
Repair Method
LED
Error Display
Dual 8
Display
4 minutes after protection stop of compressor, the malfunction is shown in error code.
In other situation, the malfunction will be displayed by press the light button for 6 times within 4 seconds.
NOTE
35
Содержание SAP-CRV12AEH
Страница 13: ...3 DIMENSIONAL DATA Indoor Unit SAP KRV9AEH SAP KRV12AEH 770 201 283 548 5 258 5 126 5 770 283 13 ...
Страница 14: ...Outdoor Unit SAP CRV9AEH SAP CRV12AEH 708 658 275 550 317 470 299 14 ...
Страница 67: ...INSTRUCTION MANUAL SAP KRV9AEH SAP CRV9AEH SAP KRV12AEH SAP CRV12AEH OI 852 6 4181 180 00 1 APPENDIX A A 1 ...
Страница 107: ......
Страница 108: ...SANYO Electric Co Ltd Osaka Japan June 2010 Printed in Japan B ...