<Outline>
The discharge pipe temperature is used as the compressor's internal temperature.
If the discharge pipe temperature rises above a certain level, the operating frequency upper limit is set to keep
this temperature from going up further.
<Detail>
•
Divide the Zone
•
Management within the Zones
7-2-4. Discharge Pipe Control
<Outline>
Detect an input current by the CT during the compressor is running, and set the frequency upper limit from
such input current.
In case of heat pump model, this control is the upper limit control function of the frequency which takes priority
of the lower limit of 4-way valve activating compensation.
When a "stop current" continues for 2.5 seconds after rushing on the stop zone, the compressor operation stops.
If "drooping current" is continues for 1.0 second after rushing on the drooping zone, the frequency will be 2Hz
drooping.
Repeating the above drooping continues until the current rushes on the drooping zone without change.
In the keeping zone, the frequency limit will remain.
In the return and reset zone, the frequency limit will be cancelled,
<Detail>
The frequency control will be made within the following zones.
7-2-5. Input Current Control
Zone
Control Contents
Stop zone
When the temperature reaches the stop zone, stop the compressor and
correct abnormality
Start the timer, and the frequency will be drooping.
Keep the upper limit of frequency.
Cancel the upper limit of frequency.
Drooping zone
Keep zone
Return / Reset zone
Heat exchanger
thermistor
temperature
Stop zone
Drooping zone
Keep zone
Up zone
Reset zone
2 Hz drooping
1.0second after
rushing in the
drooping zone
After 2.5 seconds
Compressor stops
Stop zone
Drooping zone
Keep zone
Reset zone
1
2
3
30
Содержание SAP-CRV12AEH
Страница 13: ...3 DIMENSIONAL DATA Indoor Unit SAP KRV9AEH SAP KRV12AEH 770 201 283 548 5 258 5 126 5 770 283 13 ...
Страница 14: ...Outdoor Unit SAP CRV9AEH SAP CRV12AEH 708 658 275 550 317 470 299 14 ...
Страница 67: ...INSTRUCTION MANUAL SAP KRV9AEH SAP CRV9AEH SAP KRV12AEH SAP CRV12AEH OI 852 6 4181 180 00 1 APPENDIX A A 1 ...
Страница 107: ......
Страница 108: ...SANYO Electric Co Ltd Osaka Japan June 2010 Printed in Japan B ...