PLC-HP7000L Expand Serial Command Functional Specifications
85/94
Unacceptable “Error Code” [CR]
9.10.25 CR_ CMTGG_%1 Command
Command “CR_CMMTGG_%1” [CR]
Details
Get “g” value of Target of Color matching
Acceptable
“000_%2” [CR]
%1
“RED” ---------------------- value of Red is selected
“GREEN” ----------------- value of Green is selected
“BLUE” -------------------- value of Blue is selected
“WHITE” ------------------ value of White is selected
“CYAN” -------------------- value of Cyan is selected
“MAGENTA” ------------- value of Magenta is selected
“YELLOW” --------------- value of Yellow is selected
%2
“0000”-”1000”------------ “g” value of color of %1
Response
Unacceptable “Error Code” [CR]
9.10.26 CR_ CMAUTOTESTPAT Command
Command “CR_CMAUTOTESTPAT” [CR]
Details
Get setting status of Auto test pattern of Color matching
Acceptable
“000_%1” [CR]
%1
“ON” ---------------------- On is selected
“OFF” --------------------- Off is selected
Response
Unacceptable “Error Code” [CR]
9.10.27 CR_ CMMSTESTPAT Command
Command “CR_CMMSTESTPAT” [CR]
Details
Get setting status of Test pattern(Measured) of Color matching
Acceptable
“000_%1” [CR]
%1
“RED” ---------------------- Red is displayed
“GREEN” ----------------- Green is displayed
“BLUE” -------------------- Blue is displayed
“OFF” -----------------------Test pattern display is not displayed
Response
Unacceptable “Error Code” [CR]
9.10.28 CR_ CMTGTESTPAT Command
Command “CR_CMTGTESTPAT” [CR]
Details
Get setting status of Test pattern(Target) of Color matching
Acceptable
“000_%1” [CR]
%1
“RED” ---------------------- Red is displayed
“GREEN” ----------------- Green is displayed
“BLUE” -------------------- Blue is displayed
“WHITE” ------------------ White is displayed
“CYAN” ------------------- Cyan is displayed
“MAGENTA” ------------- Magenta is displayed
“YELLOW” --------------- Yellow is displayed
“OFF” -----------------------Test pattern display is not displayed
Response
Unacceptable “Error Code” [CR]