9.7.15 CR_IDSLOT1 Command
Command
“CR_IDSLOT1” [CR]
Details
Get ID information of Input1. This command is to determine sources possible to
input.
Acceptable
“000_%1” [CR]
%1
“32” --------------- On-board (HDMI and D-Sub)
Available source: DIGITAL, ANALOG, SCART, HDCP, HDMI
Response
Unacceptable “Error Code” [CR]
9.7.16 CR_IDSLOT2 Command
Command
“CR_IDSLOT2” [CR]
Details
Get ID information of Input2. This command is to determine sources possible to
input.
Acceptable
“000_%1” [CR]
%1
“41” --------------- On-board (5BNC)
Available source: ANALOG, VIDEO, YPBPR
Response
Unacceptable “Error Code” [CR]
9.7.17 CR_IDSLOT3 Command
Command
“CR_IDSLOT3” [CR]
Details
Get ID information of Input3. This command is to determine sources possible
to input.
Acceptable
“000_%1” [CR]
%1
“51” --------------- On-board (3BNC and S-VIDEO)
Available source: VIDEO, S-VIDEO, YPBPR
Response
Unacceptable “Error Code” [CR]
9.7.18 CR_IDSLOT4 Command
Command
“CR_IDSLOT4” [CR]
Details
Get ID information of Input4. This command is to determine sources possible
to input.
Acceptable
“000_%1” [CR]
%1
“13” --------------- PJ-Net (Viewer capable)
Available source: Network
*With PJ-Net unattached, this command is invalid and error
code “103” is returned.
*With PJ-Net attached and the power OFF, error code “101” is
returned.
*In models not supporting PJ-Net, error code “103” is returned.
Response
Unacceptable “Error Code” [CR]