PLC-HP7000L Expand Serial Command Functional Specifications
76/94
9.8.6 CR_ KYSTNMODE Command
Command
“CR_KYSTNMODE” [CR]
Details
Get setting status of Keystone Store Mode
Acceptable
“000_%1” [CR]
%1
“STR” ---------------------- Store mode is “Store”
“RST” ---------------------- Store mode is “Reset”
Response
Unacceptable “?” [CR] -------------------- When unknown command is received
9.8.7 CR_CORNERTESTPAT Command
Command
“CR_CORNERTESTPAT” [CR]
Details
Get setting status of test pattern for Corner correction
Acceptable
“000_%1” [CR]
%1
“RED” ---------------------------- Test pattern is red
“WHITE” ------------------------- Test pattern is white
“BLUE” --------------------------- Test pattern is blue
“OFF” ------------------------- Test pattern is not displayed
Response
Unacceptable “Error Code” [CR]
9.8.8 CR_CEIL Command
Command
“CR_CEIL” [CR]
Details
Get setting status of Ceiling
Acceptable
“000_%1” [CR]
%1
“ON” --------------------------- Ceiling projection is enabled
“OFF” ------------------------- Ceiling projection is disabled
Response
Unacceptable “Error Code” [CR]
9.8.9 CR_REAR Command
Command
“CR_REAR” [CR]
Details
Get setting status of Rear function
Acceptable
“000_%1” [CR]
%1
“ON” --------------------------- Rear projection is enabled
“OFF” ------------------------- Rear projection is disabled
Response
Unacceptable “Error Code” [CR]
9.8.10 CR_SCREENASPECT Command
Command “CR_SCREENASPECT”[CR]
Details
Get status of Screen aspect
Acceptable
“000_%1”[CR]
%1
“43MODE”
・・・・・・・
Select 4
:
3 mode
“169MODE”
・・・・・・
Select 16
:
9 mode
“1610MODE”
・・・・・・
Select 16
:
10 mode
Response
Unacceptable “Error code”[CR]