PLC-HP7000L Expand Serial Command Functional Specifications
40/94
8.9 Setting Command
8.9.1 CF_LANG Command
Command “CF_LANG_%1” [CR]
%1
“ENG” --------------------------- Select ENGLISH
“DEU” --------------------------- Select German
“FRA” --------------------------- Select French
“ITA” ----------------------------- Select Italian
“ESP” ---------------------------- Select Spanish
“POR” --------------------------- Select Portuguese
“NED” --------------------------- Select Dutch
“SVE” --------------------------- Select Swedish
“JPN” --------------------------- Select Japanese
“CHI” ---------------------------- Select Chinese
“KOR” --------------------------- Select Korean
“RUS” --------------------------- Select Russian
Details
Set language for OSD (Available only in the normal Power ON status)
The language set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.2 CF_MENUPOSITION Command
Command “CF_MENUPOSITION_%1” [CR]
%1
“UP” ----------------------------- Move Menu position to upper side.
“DN” ----------------------------- Move Menu position to lower side.
“LEFT” -------------------------- Move Menu position to left side.
“RIGHT” ------------------------ Move Menu position to right side.
Details
Move Menu position. (Valid only when in the normal Power ON status.)
This function is worked from the first reception of Command.
*
When setting beyond the area of movement is carried out, return “101” [CR] and
the command is not executed.
Ex.) When movement to right side has already reached limit; and "RIGHT" is
received.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.3 CF_MENUSIZE Command
Command “CF_MENUSIZE_%1” [CR]
%1
“NORMAL” -------------------- Select Menu size to Normal.
“DOUBLE” --------------------- Select Menu size to Double.
Details
Select Menu size. (Valid only when in the normal Power ON status.)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]