PLC-HP7000L Expand Serial Command Functional Specifications
82/94
%1
“1” -------------------- 10% is selected(Main size)
“2” -------------------- 20% is selected(Main size)
“3” -------------------- 30% is selected(Main size)
“4” -------------------- 40% is selected(Main size)
“5” -------------------- 50% is selected(Main size)
“6” -------------------- 60% is selected(Main size)
“7” -------------------- 70% is selected(Main size)
“8” -------------------- 80% is selected(Main size)
“9” -------------------- 90% is selected(Main size)
“10” ------------------ 100% is selected(Main size)
%2
“1” -------------------- 10% is selected(Sub size)
“2” -------------------- 20% is selected(Sub size)
“3” -------------------- 30% is selected(Sub size)
“4” -------------------- 40% is selected(Sub size)
“5” -------------------- 50% is selected(Sub size)
Unacceptable “Error Code” [CR]
9.10.14 CR_PIPFRAMELOCK Command
Command “CR_PIPFRAMELOCK” [CR]
Details
Get setting status of Frame lock in “Picture in Picture”.
Acceptable
“000_%1” [CR]
%1
“MAIN” -------------------- Main picture is selected
“SUB” --------------------- Sub picture is selected
Response
Unacceptable “Error Code” [CR]
9.10.15 CR_PIPSTORE Command
Command “CR_PIPSTORE” [CR]
Details
Get status (Free or Stored) of User1-User5 for “Picture in Picture”.
Data consists of 5 bytes and each byte represents User1-5. (F:Free, S:Stored)
Acceptable
“000_%1” [CR]
%1
“SFFFF” -------------------- Only User1 is Stored, others are Free
:
“FFFFS” --------------------- Only User5 is Stored, others are Free
“SSSSS” -------------------- All Stored
Response
Unacceptable “Error Code” [CR]
9.10.16 CR_EDGEBLENDING Command
Command “CR_EDGEBLENDING” [CR]
Details
Get setting status of Edge blending
Acceptable
“000_%1” [CR]
%1
“ON” ---------------------- On is selected
“OFF” --------------------- Off is selected
Response
Unacceptable “Error Code” [CR]
9.10.17 CR_BLEND Command
Command “CR_BLEND” [CR]
Details
Get all values set for Width in Edge blending
Response Acceptable
“000_%1_%2_%3_%4” [CR]