PLC-HP7000L Expand Serial Command Functional Specifications
49/94
%1
“ON” ---------------------- Set to On
“OFF” -------------------- Set to Off
Details
Set Auto test pattern of Color matching.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.33 CF_CMRST Command
Command “CF_CMRST_%1” [CR]
%1
“CMRST” ---------------------- Reset setting of Color matching
“ADCRST” -------------------- Reset setting of Advanced color matching
Details
Reset setting of Color matching.(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.34 CF_CMSTORE Command
Command “CF_CMSTORE_%1” [CR]
%1
“CMSTR” ---------------------- Store setting of Color matching
“ADCSTR” -------------------- Store setting of Advanced color matching
Details
Store setting of Color matching.(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.35 CMMSTESTPAT Command
Command “CF_CMMSTESTPAT_%1” [CR]
%1
“RED” ---------------------- Display Red
“GREEN” ------------------ Display Green
“BLUE” -------------------- Display Blue
“OFF” --------------------- Do not show test pattern display
Details
Display Test pattern of Measured of Color matching.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.36 CF_CMTGTESTPAT Command
Command “CF_CMTGTESTPAT_%1” [CR]
%1
“RED” ---------------------- Display Red
“GREEN” ------------------ Display Green
“BLUE” -------------------- Display Blue
“WHITE” ------------------ Display White
“CYAN” -------------------- Display Cyan
“MAGENTA” ------------- Display Magenta
“YELLOW” --------------- Display Yellow
“OFF” --------------------- Do not show test pattern display
Details
Display Test pattern of Target of Color matching.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response