1-11 Installation Instructions
Selecting the Installation Site
■
Wind Shield for “GHL”, “GL” Model
It is recommended to install wind shields for cooling
operation in low outdoor temperature condition.
(Fig. 1-10)
General
When the outdoor unit is installed in a position ex-
posed to strong wind (like seasonal winds with low air
temperature in winter), wind shield must be installed
on the outdoor unit.
This unit is designed so that the fan of the outdoor unit
runs at low speed when the air conditioner is operated
at low outdoor air temperatures. When the outdoor unit
is exposed to strong wind, the system pressure drops
because of the freeze protector.
For outer dimensions of wind shield, please see
Fig. 1-11.