5. Vertical Size Adjustment
[Adjusting Location]
VR972
[Adjustment
I
Check]
Measuring Point
Measuring Equipment
Viewfinder
Condition
Playback
Input Signal
I
Alignment Tape
ADJ. Location
VR972
Preparation:
(WR5-5CSP) : For operation check,
monoscope portion
ADJ. / Check Value
• POWER switch: "PLAYER"
Adjustment:
1 . Turn and adjust VR972 within 87.5 to 92.5 on the vertical
size scale of the monoscope signal.
6.
Brightness Adjustment
[Adjusting Location]
VR975
[Adjustment
I
Check]
Measuring Point
Measuring Equipment
Viewfinder
Condition
Playback
Input Signal
I
Alignment Tape
ADJ. Location
VR975
Preparation:
(WR5-5CSP): For operation check,
monoscope portion
ADJ. / Check Value
• POWER switch: "PLAYER"
Adjustment:
1 . Adjust to adequate brightness with VR975.
- 5-28 -