3. Zooming Curve Adjustment
[Connection]
[Adjustment]
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ
Measuring Point
Measuring Equipment
J9001 @)
Digital voltmeter
[ADJ. END]
J9001
@)
[GND]
Subject
Condition
Power
OFF -+ ON
Siemens star (from lens surface: 1 1 0-
1 50 cm, illuminance: 50 to 1 20 lux)
ADJ. Location
ADJ. Value
Preparation:
•
Short pin
CD
and pin ®
,
then short pin ® and pin
@)
of
J9001 .
Adjusting method:
1 . Turn on the power by changing the Stand-by switch from
"POWER SAVE" to "STANDBY".
2. The DC voltage of J9001 @) will change from High (4 - 5
V) to Low (below 1 V), and the adjustment will be
completed. (About 1 5 seconds)
NOTES:
•
When the power is turned on, the focus adjusts on the
subject (Siemens star). After the focus has been adjusted ,
the screen will blackout for a few seconds. When the
screen picture returns, the adjustment is completed.
•
Focus Position Adjustment should be completed before
hand.
VSUB
E
f
G
h
J
K
L
m
abbreviation
N
Voltage [VJ
9.0 9.5 1 0.0 1 0.5 1 1 .0 1 1 .5 1 2.0 1 2.5 1 3.0
4. CCD Driving Voltage Adjustment
[Connection]
[Adjustment]
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ
Measuring Point
Measuring Equipment
J9001
®
Digital voltmeter
[VSUB]
J9001 ®
Subject
[PGL]
J9001
@)
[GND] No designation
Condition
CAMERA EE
ADJ. Location
ADJ. Value
EVR CH1 [VSUB]
Abbreviation voltage value
EVR CH2 [PGL]
±
0.1
v
Preparation:
•
Short pin
CD
and pin ® , then short pin ® and pin
@)
of
J9001 .
Adjusting method:
1 . Read the abbreviation of two digits displayed on the rear
side of CCD. The first digit displays PG L and the second
digit displays VSUB. Convert these to the voltage with the
table below.
For example, [4R] displays PGL
=
2.5 V, VSUB
=
1 4.5 V
2. Operate the CH-UP key or the CH-DOWN key to
designated EVR CH1 .
3. Operate the DATA-CENT key, DATA-U P key and DATA
DOWN key so that the voltage at [VSUB] becomes the
displayed voltage value
±
0.1 V.
4. Press the WRT key to store the adjusting data.
5. Repeat steps 2. - 4., and use the WRT key to adjust in
the same manner the EVR CH2 [PGL] displayed voltage
value
±
0.1 V.
PGL
1
2
3
4
5
6
7
abbreviation
Voltage [VJ
1 .0 1 .5 2.0 2.5 3.0 3.5 4.0
p
Q
R
s
T
u
v w x
y
z
1 3.5 1 4.0 1 4.5 1 5.0 1 5.5 1 6.0 1 6.5 1 7.0 1 7.5 1 8.0 1 8.5
- 5-5 -