1 3. REC Y Recording Current Adjustment
[Connection]
VR1 81
�
[Adjustment
I
Check]
TP1 41
0
TP1 91
QCH2
0
EXT
Measuring Point
Measuring Equipment
Condition
TP1 91 (CH 1 )
Oscilloscope
Record
TP1 41 (GND)
M P type tape
Input Signal
I
Alignment Tape
No signal
ADJ. Location
ADJ.
I
Check Value
VR1 81
1 70 ± 20 mVp-p
Preparation:
• POWER switch: "CAMERA"
• Stand-by switch: "STANDBY"
• Short pin ® , pin @ and pin ® of J1 005.
Adjusting
I
Checking method:
1 . Adjust with VR1 81 so that the recording level is 1 70 ±
20 mVp-p.
1 70 ± 20 mVp-p
0.23µ sec
14. REC C Recording Current Adjustment
[Connection]
TP1 05
[Adjustment
I
Check]
TP1 41
0
TP1 32
� VR1 31
CHl
QCH2
EXT
Measuring Point
Measuring Equipment
Condition
TP1 32 (CH 1 )
Oscilloscope
Record
TP1 05 (EXT)
M P type tape
TP1 41 (GND)
Input Signal
I
Alignment Tape
Color bar
ADJ. Location
ADJ.
I
Check Value
VR1 31
200 ± 15 mVp-p
Preparation:
• POWER switch: "CAMERA"
• Stand-by switch: "STANDBY"
• Short pin @ , pin @ and pin ® of J1 005.
Adjusting
I
Checking method:
1 . Adjust with VR1 31 so that the burst level becomes 200
± 15 mVp-p.
Burst
200 ± 1 5 mVp-p
- 5-2 1 -