8.3 Trouble shooting when alarm activated
8-22
8
Maintenance
■
Alarm Code 62 (Main Circuit Under-voltage)
DC Main circuit low voltage
Status at the time of alarm
Cause
1
2
3
4
5
Issued when control power is turned ON.
✔
✔
Issued when main circuit power supply is
turned ON.
✔
✔
✔
Issued during operation.
✔
✔
Corrective
actions
Cause
Investigation and corrective actions
1
■
Input power supply voltage is below the
specified range.
■
Check the power supply and set it within
the specified range.
2
■
Rectifier of main circuit is broken.
■
Replace the servo amplifier.
3
■
Input power supply voltage is reduced, or
instantaneous power interruption is
occurred.
■
Check the power supply, and confirm that
there is no instantaneous power
interruption or low voltage.
4
■
Low voltage outside of the specified
range is supplied to the main circuit
(R/S/T).
■
Check the main circuit voltage. Confirm
that there is no external power supply to
R/S/T when the main circuit is OFF.
5
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
■
Alarm Code 63 (Main Power Supply phase loss)
1 phase of the 3 phase main circuit power supply disconnected
Status at the time of alarm
Cause
1
2
3
Issued when control power is turned ON.
✔
Issued when main circuit power supply is
turned ON
✔
✔
✔
Issued during operation.
✔
✔
Corrective
actions
Cause
Investigation and corrective actions
1
■
One of 3 phases (R/S/T) is not
connected.
■
Check the wiring conditions and correct it
if improper.
2
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
3
■
Servo amplifier is not specified for single
phase.
■
Change the Index 0x20FD-1 "Main circuit
power input type [MPWRIN]" to "0x01
:
1
φ
AC ".
■
Alarm Code 68 (Main circuit voltage detection error)
Failure of VBUS detection circuit
Status at the time of alarm
Cause
1
Issued when control power is turned ON.
✔
Corrective
actions
Cause
Investigation and corrective actions
1
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
Содержание SANMOTION 3E S
Страница 1: ...M0011696D Instruction Manual TYPE S For Rotary Motor Linear Motor Interface ...
Страница 2: ......
Страница 182: ...No Text on This Page ...
Страница 200: ...No Text on This Page ...
Страница 270: ...No Text on This Page ...
Страница 336: ...No Text on This Page ...
Страница 384: ...No Text on This Page ...
Страница 408: ...No Text on This Page ...
Страница 419: ...12 3 Servo motor dimensions 12 9 12 Appendix 12 3 Servo motor dimensions Refer another document M0011792 ...
Страница 420: ...12 Appendix 12 10 12 4 Servo motor data sheet Refer another document M0011792 ...
Страница 421: ...12 5 Servo amplifier dimensions 12 11 12 Appendix 12 5 Servo amplifier dimensions 12 5 1 RS3 01A HL 12 5 2 RS3 02A HL ...
Страница 422: ...12 Appendix 12 12 12 5 3 RS3 03A HL 12 5 4 RS3A05A HL ...
Страница 423: ...12 5 Servo amplifier dimensions 12 13 12 Appendix 12 5 5 RS3A07A HL 12 5 6 RS3A10A HA ...
Страница 424: ...12 Appendix 12 14 12 5 7 RS3A15A HA 12 5 8 RS3A30A HL ...
Страница 425: ...12 5 Servo amplifier dimensions 12 15 12 Appendix 12 5 9 Power unit RS3PAA270 12 5 10 Amplifier unit RS3W60 ...
Страница 426: ...12 Appendix 12 16 12 5 11 Unit installation drawing 600 A RS3PAA270 Power unit RS3W60 Amplifier unit ...
Страница 428: ...12 Appendix 12 18 12 5 13 RS3C02A HA 12 5 14 RS3C05A HA ...
Страница 429: ...12 5 Servo amplifier dimensions 12 19 12 Appendix 12 5 15 RS3C10A HA 12 5 16 RS3C15A HL ...
Страница 430: ...12 Appendix 12 20 12 5 17 RS3C30A HM ...
Страница 448: ...12 Appendix 12 38 For RS3A10 RS3A15 AL 00907039 01 For RS3A30 AL 00907040 01 Common parts Upper Bottom Upper Bottom ...
Страница 484: ...12 Appendix 12 74 REGIST 1000W Wiring diagram ...
Страница 486: ...No Text on This Page ...
Страница 487: ...Release Revision A Sep 2017 Revision B Sep 2018 Revision C Dec 2018 Revision D Apr 2019 ...