5.Parameter
[Parameter setting value【Group3】【Group4】]
5−12
Page
Contents
Vibration Suppressor Frequency 2
[SUPFRQ2]
40
Setting range
Unit
Standard
value
5
〜
500
Hz 500
Parameter to set the frequency of vibration suppressing
vibration.
In the servo amplifier, the vibration suppressing frequency
from 5 to 99Hz is treated by 1Hz unit, and from 100 to
500Hz is by 10Hz unit. Operations do not change if set by
lower unit than these.
Vibration suppressing control is disabled when the set
value is 500Hz.
✍
Change this while the motor stops.
Vibration Suppressor Frequency 3
[SUPFRQ3]
41
Setting range
Unit
Standard
value
5
〜
500
Hz 500
Parameter to set the frequency of vibration suppressing
vibration.
In the servo amplifier, the vibration suppressing frequency
from 5 to 99Hz is treated by 1H unit, and from 100 to
500Hz is by 10Hz unit. Operations do not change if set by
lower unit than these.
Vibration suppressing control is disabled when the set
value is 500Hz.
✍
Change this while the motor stops.
Vibration Suppressor Frequency 4
[SUPFRQ4]
42
Setting range
Unit
Standard
value
5
〜
500
Hz 500
Parameter to set the frequency of vibration suppressing
vibration.
In the servo amplifier, the vibration suppressing frequency
from 5 to 99Hz is treated by 1H unit, and from 100 to
500Hz is by 10Hz unit. Operations do not change if set by
lower unit than these.
Vibration suppressing control is disabled when the set
value is 500Hz.
✍
Change this while the motor stops.
■
General parameter
Group 4
[
High setting control settings
]
Page
Contents
Command Velocity, Low Pass Filter
[CVFIL]
00
Setting range
Unit
Standard
value
1
〜
2000
Hz 1000
Sets the cut off frequency of low pass filter, when
command velocity is calculated. When the position
command resolution is low, lower the cut off frequency.
Filter is disabled when the set value is 2000Hz.
Command Velocity Threshold
[CVTH]
01
Setting range
Unit
Standard
value
0
〜
65535
min
-1
20
When the command velocity calculated from position
command is larger than this threshold, acceleration or
deceleration compensation will be performed.
Acceleration Compensation
[ACCCO]
02
Setting range
Unit
Standard
value
-9999
〜
+9999
×
50
Pulse
0
Compensation at acceleration.
Deceleration Compensation [DECCO]
03
Setting range
Unit
Standard
value
-9999
〜
+9999
×
50
Pulse
0
Compensation at deceleration.
Содержание Q1AA04003D
Страница 3: ...TYPE S M0006890C Analogue Pulse Input Type Instruction Manual For Rotary Motor E N G L I S H ...
Страница 156: ...8 Maintenance Trouble Shooting 8 1 Alarm List 8 3 Trouble shooting when Alarm Occurs 8 5 Inspection Parts Overhaul 8 25 ...
Страница 238: ...Materials Dimension RS1 10 Materials 27 TION M TION M ...
Страница 239: ...Materials Dimension RS1 15 Materials 28 M TION TION M ...
Страница 240: ...Materials Dimension RS1 30 Materials 29 TION M TION M ...
Страница 256: ...Materials Option Metal mounting fittings Materials 45 AL 00582789 01 AL 00582791 01 ...
Страница 257: ...Materials Option Metal mounting fittings Materials 46 AL 00582790 01 AL 00582792 01 ...