4. Digital Operator
[
Monitor mode operations and display]
4−4
Overload warning status
If operation is kept on, alarm may be issued.
Regenerative overload warning status
If operation is kept on, alarm may be issued.
Battery warning status
Replace the battery.
Alarm display
When an alarm rings, take corrective actions as instructed in “Chapter 8,
Maintenance”.
●
In addition to the above, warning functions include “excessive deviation warning” and “amplifier
temperature warning”, which can be confirmed at monitor mode.
●
There is a possibility that an overload warning will be detected when the control power is supplied, if the
overload warning level is set below 75% (generic parameter GroupB Page22), because a rated load of 75%
(hot start) has been assumed for the overload detection process when control power is supplied.
■
Description of monitor mode
●
Various contents can be monitored as shown below at each page of monitor mode.
Pag
e
Name Contents
Unit
Display form
00 Servo
amplifier
status
Main circuit power supply status. Operation preparation
status. Servo ON status: Servo ON
Displays the status of servo amplifier, as mentioned above.
--- Code
01
Warning status 1
Displays warning status.
---
02
Warning status 2
Displays warning status.
---
03
General input CONT8~1 monitor
Displays the status of the general input terminal.
---
04
General output OUT8~1 monitor
Displays status of general output terminal.
---
Bit
05
Velocity monitor
Displays number of motor rotations.
min
-1
06
Velocity command monitor
Displays velocity command value.
min
-1
07
Torque monitor
Displays output torque of motor.
%
08
Torque command monitor
Displays torque command value.
%
Decimal
09
Position deviation monitor
Displays position deviation value.
Pulse
0A
Current position monitor
(Motor encoder)
0B
Current position monitor
(External encoder)
0C
Command position monitor
Displays the current position assumed that the position at the time
of control power turn-ON is origin. This is a free run counter,
therefore, if the current position exceeds the displayed range, the
maximum value of reverse polarity will be displayed.
Pulse
32 bit data
Hexadecimal
0D
Analog velocity command / analog
torque command input voltage
Displays entered command voltage.
mV
0E
Position command pulse monitor
(Position command pulse input
frequency)
Displays entered command pulse frequency.
k Pulse
/s
0F
U-phase electric angle monitor
Always displays U-phase electric angle, excluding
encoder(sensor) errors.
deg
Decimal
10
Absolute encoder PS data (Upper)
Displays position data PS of absolute encoder.
x2^32 P
11
Absolute encoder PS data (Lower)
Displays position data PS of absolute encoder.
Pulse
32 bit data
Hexadecimal
12
Regenerative resistance run rate
Displays run rate of regenerative resistance.
%
13
Motor usage ratio monitor
Displays the accurate value, however, it may sometimes take
several hours for the value to become stable depending on the
operation pattern..
%
14
Motor usage ratio monitor
(Estimated value)
Displays estimated value of the servo motor usage ratio.
Estimated from brief operation. In an application where the same
operation pattern repeats in a short time, the usage ratio can be
confirmed soon.
%
Decimal
✍
Содержание Q1AA04003D
Страница 3: ...TYPE S M0006890C Analogue Pulse Input Type Instruction Manual For Rotary Motor E N G L I S H ...
Страница 156: ...8 Maintenance Trouble Shooting 8 1 Alarm List 8 3 Trouble shooting when Alarm Occurs 8 5 Inspection Parts Overhaul 8 25 ...
Страница 238: ...Materials Dimension RS1 10 Materials 27 TION M TION M ...
Страница 239: ...Materials Dimension RS1 15 Materials 28 M TION TION M ...
Страница 240: ...Materials Dimension RS1 30 Materials 29 TION M TION M ...
Страница 256: ...Materials Option Metal mounting fittings Materials 45 AL 00582789 01 AL 00582791 01 ...
Страница 257: ...Materials Option Metal mounting fittings Materials 46 AL 00582790 01 AL 00582792 01 ...