Mode Setting Function
This Controller can switch the control target of [in2 Input].
The functions that the
“
io
”
mode setting can perform:
①
Switching of the
“
io
”
mode
②
Initialization of the set data [Reset to the factory setting]
Function
Control target
io01
Controls the feeder output in [in2 Input]. [with overflow stop] (factory setting)
io02
Does not control the feeder output in [in2 Input]. [without overflow stop]
io03
[in2 Input] is pattern switching input [Lo fixed].
io04
[in2 Input] is pattern switching input [hi fixed].
99
Initializes the set data [Resets to the factory setting].
1)
“
io
”
mode switching method
(1) When the power supply to the Controller is OFF, power ON the Controller by pressing both
the Vol
▲
key and the Freq
▼
key together.
(2) The data display area displays “io01” to start the Controller.
※
If the Controller starts in a normal manner, redo the above (1) and (2).
(3) Press the Freq
▲
key to select the
“
io
”
mode to be used.
The display switches
“
io01
”
→
“
io02
”
→
“
io03
”
→
“
io04
”
→
“
99
”
→
“
io01
”
in this
order.
When the Freq
▼
key is pressed, the display area switches them in the reverse order.
(4) Press the Set key long for 2 sec to start the controller in a normal manner in the selected
“
io
”
mode.
For example, when “io02” is selected, “io02” is displayed when the “
io
”
mode is displayed
upon powering ON the controller.
2) Motion in each
“
io
”
mode
According to the selected
“
io
”
mode, the functional assignment of the input signals (in1
–
3) are
differing as follows:
Function of input signal
Signal name
io01 / io02
io03 / io04
in1
External signal input
External signal input
in2
Overflow sensor input
Pattern switching input 2
in3
Pattern switching input 1
Pattern switching input 1