33/36
14. Troubleshooting
Trouble
Probable cause
Corrective action
The feeder does not vibrate.
The power cable is not connected.
Connect the power cable.
“Voltage (%)” is “0.0.”
Set “Voltage(%).”
The set frequency is wrong.
Adjust the frequency to the
resonance frequency.
The output connectors is disconnected
from the feeder.
Connect the output connector to
the feeder.
The RUN lamp is OFF.
Check the external control and the
overflow sensor.
Check the parameter settings.
The RUN lamp is blinking.
Press the ON/OFF key
Voltage(%) cannot be set.
The AUTO lamp is ON. (The mode is the
“
A
”
mode.)
Switch the mode to the
“
n
”
mode.
The frequency cannot be
adjusted.
The AUTO lamp is ON. (The mode is the
“
A
”
mode.)
Switch the mode to the
“
n
”
mode.
The F-LOCK lamp is ON in the
“
n
”
mode. Release the lock.
When the power supply is
turned OFF, the voltage and
frequency settings disappear.
The data has not yet been saved.
Save the data.
The overcurrent error (E-01)
is displayed.
The feeder is probably abnormal.
Contact the dealer.
Ground fault was caused due to damage
to the controller output cable cover or
the feeder wire cover.
Replace the damaged cable or wire.
The frequency is deviant.
Adjust the frequency to the
resonance frequency.
The search range for the automatic
tuning of frequency is not appropriate.
Set the parameter No. 05 according
to the feeder in use.
When the controller is
operated, the E-09 error
occurs.
The controller was operated in
connection to a large-sized feeder while
the vibration was adjusted to a
small-sized feeder.
Redo the vibration adjustment.
One of the memory errors
(E-10
–
12) occurs when the
controller starts.
There was a memory error when the
power supply was turned ON.
Reset the power supply.
If the same error recurs, contact
our sales agent for consultation.
15. Options
Name
Applied wire
Length (mm)
Terminal
Remarks
Power cable
VCTF 0.75x3
1200
Nichifu pin terminal male
PC-2005M
Mounting
as standard
Output cable
VCTFK 0.75x2
1200
Molex terminal
1189ATL
Molex housing 3P
1396R1
Overflow sensor
input cable (P3 cord)
VCTF 0.3x3
300
Molex terminal
1381ATL
Molex housing 3P
1396R1
Vibration sensor
input cable (P4 cord)
MOGAMI 2330
(Low Noize Wire)
1200
Molex terminal
1189ATL
Accessory
Molex housing 2P
1545R1
Vibration sensor
(KS-3)
MOGAMI 2330
(Low Noize Wire)
1000
Molex terminal
1190TL
Sold
separately
Molex housing 2P
1545P1
Vibration sensor
input extension cable
MOGAMI 2330
(Low Noize Wire)
2000
Molex terminal
1190TL/1189ATL
Molex housing 2P
1545P1/1545R1