-A Adjustment of the feedback gain (PI control gain)
Vol
▼
key
Set key
Freq
▲▼
keys
Set key
The operation described in this section is
performed if the speed variation repeats
pulsating (becoming faster and slower).
Adjust the output reaction to the vibration
sensor signal.
Perform this operation when the feeder is
in operation.
※
Change this value to change
the reaction speed.
Switch the parameter
No. to “0P.”
※
The value can be changed within a range
of 1
-
9.
The smaller the value is, the slower the
reaction is. The larger the value is, the
faster the reaction is.
※
<If the start is slow>
If the slow start is not improved even if the
number of seconds of the parameter No. 0C
(soft start) is made smaller, raise the value
of the parameter No. 0P (reaction speed),
and the slow start may be improved.