background image

10 

 

  Although the appliance has a power switch, a single pole switch with a minimum gap of 

3 mm between contacts and adequate for the total current must be fitted between the 
appliance and the mains, in compliance with national regulations. 

 

  This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. Children must be supervised to ensure that they do 
not play with the product. 

  Children must be supervised to ensure that they do not play with the product. 

  Before  carrying  out  any  maintenance  or  cleaning  operations,  always  disconnect  the 

hood from the mains. 

 

  When  replacing  bulbs  always  use  bulbs  of  the  same  type  and  power,  never  more 

powerful.   
 

  If  the  cleaning  operations  are  not  done  respecting  the  instructions  indicated  in 

« OPERATION AND MAINTENANCE », there is risk of fire. 

 

 

THE  MANUFACTURER  WILL  NOT  BE  HELD  LIABLE  FOR  DAMAGES  TO  PEOPLE 
AND/OR PROPERTY DUE TO NON-COMPLIANCE WITH THESE WARNINGS. 

 

 

2. INSTALLATION 

 

The assembly and electrical connections should be carried out by a qualified technician. 

 

2.1.- Electrical connection 

The  unit  is  of  the  double  insulated 

,  therefore  does  not  require  an  earth 

connection. 

 

  Make sure the mains voltage and frequency coincide with those on the characteristics 

plate on the hood and the remote extraction unit. 

 

  The electrical connection must be carried out as follows: 

 

Brown    =        L (Line) 

 

 

Blue          =      N (Neutral) 

 

  Although this is a device with a switch, When installing the hood, it is advisable to fit it in 

such a manner that the mains plug is accessible by the user. 

(Fig.2)

 

 

  In case of direct connection to the mains, the installer has a connection card inside of 

connection box. 
 

2.2.- Fastening the hood 

 

  The hood must be centred with respect to the cooking surface, at a minimum height of 

650 mm. 

 

Содержание BOX-600 INOX N

Страница 1: ...0 900 INOX N ONDA CRISTAL 600 700 900 N Manual de instalaci n e instrucciones de uso Installation manual and operating instructions Notice d installation et d utilisation Manual de instala o e instru...

Страница 2: ...2 Fig 1 Fig 3 Fig 2 Fig 4 Fig 5 B C 6 200 230 230 235 A B 1 2 3...

Страница 3: ...3 Fig 6 Fig 9 Fig 12 Fig 7 Fig 10 Fig 8 Fig 11...

Страница 4: ...ci n y un quemador de gas horno chimenea etc que dependan del aire del ambiente y que sean alimentados con energ a no el ctrica recomendamos para un funcionamiento seguro ventilar correctamente la zon...

Страница 5: ...a bombillas de m s potencia que la indicada y siempre bombillas del mismo tipo Si las operaciones de limpieza no se realizan respetando las instrucciones indicadas en el apartado USO Y MANTENIMIENTO h...

Страница 6: ...pone de agujero de descarga al exterior deberemos solicitar al vendedor los dos filtros de carb n activo circulares los cuales son contemplados como accesorio y no est n incluidos de serie Para el mon...

Страница 7: ...realizan las operaciones de mantenimiento sobre todo de los paneles filtrantes o del filtro de carb n activo Los Paneles filtrantes sirven para detener las part culas de grasa que se encuentran en su...

Страница 8: ...e debemos adquirir con las futuras generaciones nos obligan al reciclado de materiales le rogamos que no olvide depositar todos los elementos sobrantes del embalaje en los correspondientes contenedore...

Страница 9: ...in operation simultaneously in the same room and the correct combustion of the latter appliances depends on ambient air for safe operation we recommend ventilating the room sufficiently to ensure that...

Страница 10: ...l If the cleaning operations are not done respecting the instructions indicated in OPERATION AND MAINTENANCE there is risk of fire THE MANUFACTURER WILL NOT BE HELD LIABLE FOR DAMAGES TO PEOPLE AND OR...

Страница 11: ...s standard equipment For mount them see Fig 6 Fix in the wall the plastic bracket just below the decorative telescopic support Fig 7 The two pins of the support position have to fit with the holes of...

Страница 12: ...s Remove the filters Fig 4 from the hood and wash them with a solution of water and neutral liquid detergent and leave the dirt to soften Rinse with plenty of warm water and leave to dry The filters c...

Страница 13: ...the nearest waste management point 6 TECHNICAL ASSISTANCE S P s large Technical Service network will guarantee adequate technical assistance If a fault is observed in the unit please contact any of t...

Страница 14: ...br leur une chaudi re un po le un four etc v rifier que l entr e d air neuf ext rieur dans la pi ce est correctement dimensionn e pour assurer une bonne combustion Cette entr e d air neuf ne doit pas...

Страница 15: ...l es d origine Fig 9 1 ou Fig 9 2 selon le mod le acquis Si les op rations de nettoyage ne sont pas r alis es dans le respect des instructions de UTILISATION ET ENTRETIEN il existe un risque d incendi...

Страница 16: ...u charbon actif disponibles comme accessoire et non fournis avec la hotte Pour les monter voir Fig 6 Fixer au mur la d rivation en plastique juste en dessous du support de la chemin e t lescopique Fig...

Страница 17: ...ater Pour viter le risque ventuel d incendies nettoyer les filtres au moins tous les deux mois en suivant les instructions ci apr s Retirer les filtres Fig 4 et les laver avec une solution d eau et de...

Страница 18: ...tous les l ments restants de l emballage dans les containers correspondants de recyclage et d emmener les appareils remplac s au Gestionnaire de D chets le plus proche 6 ASSISTANCE TECHNIQUE Pour tou...

Страница 19: ...ltaneamente a campanula de aspira o e um quemador de g s forno chamin etc que dependam do ar do ambiente e que sejam alimentados com energia n o el ctrica recomendamos para um funcionamento seguro ven...

Страница 20: ...a a utiliza o do aparelho As crian as devem ser supervisionadas para assegurar de que n o brincam com o aparelho Antes de realizar qualquer opera o de manuten o ou limpeza desligue a campanula da rede...

Страница 21: ...ig 5 1 Assegure se que todos os tornillos estejam bem apertados Vers o aspirante Ligue mediante um tubo de enlace de di metro 150 mm a arandela de sa da Fig 5 3 A e o orificio de descarga ao exterior...

Страница 22: ...F C Velocidade de extrac o lenta D Velocidade de extrac o m dia E Velocidade de extrac o r pida 4 MANUTEN O IMPORTANTE Antes de realizar qualquer opera o de limpeza ou manuten o desligue a campanula d...

Страница 23: ...s ap s um uso prolongado do aparelho 5 COLOCA O FORA DE SERVI O E RECICLAGEM A normativa CEE e o compromisso que devemos adquirir com as futuras gera es obrigam reciclagem de materiais pedimos que n o...

Страница 24: ...S P SISTEMAS DE VENTILACI N S L U C Llevant 4 08150 Parets del Vall s Barcelona Tel 34 93 571 93 00 Fax 34 93 571 93 01 www solerpalau com Ref 1431241 1...

Отзывы: