32 S&C Instruction Sheet 1074-530
SpeedNet Client Tool
Interfaces Window,
Serial Mode Tab
Figure 53. Serial Mode interface configuration window.
The following serial port modes are available: See Figure 53.
•
PPP
—The Point-to-Point Protocol (PPP) mode is used for emulating an Ethernet
connection over a serial interface. This is currently used for communication with a
SpeedNet ME Radio in an IntelliRupter® PulseCloser® Fault Interrupter through the
IntelliRupter fault interrupter Wi-Fi interface. SpeedNet ME Radios do not route traffic
to other radios from the PPP interface due to security concerns.
•
DNP
—The Distributed Network Protocol (DNP) mode is used for transferring DNP
data between the SpeedNet ME Radio serial port and other Ethernet devices.
Note:
The
Repeater/SpeedGate Mode
setting is not available because that function-
ality is not supported on the ME platform.
•
Apply
—Saves changes made to the
Serial Mode
window. Changes will not be saved
if you select a different configuration tab without first clicking the
Apply
button.
PPP Serial Mode
The following options are available when PPP is the selected serial port mode, as shown
in Figure 54:
•
Local IP Address
—This is the IP address (Ethernet interface) assigned to the SpeedNet
Radio’s end of the PPP link.
•
Remote IP Address
— This is the IP address assigned to the remote device of the
PPP link.
Figure 54. Point-to-point Protocol settings.