4. TROUBLESHOOTING
2) Test Mode Description
1. Forced Operation Function
1-1) When any button is pressed once at the Test Mode, it enters into the Forced
Operation. When it enters into the Test Mode, 'FF' will light up on the 7-segment
LED. With the Bar Type Display, the entire Fridge and Freezer temperature LEDs
start on. And, it indicates that it is in the Test Mode.
At this time, the Alarm starts beeping.
1-2) When the Forced Operation is selected, the compressor starts without a 7-minute
delay in any operation mode.
At this time, when it is in a Defrost mode, it stops defrosting and the Forced
Operation begins.
(If the Forced Operation begins as soon as the compressor stops, it may cause the
overload. So, take care when entering into the Forced Operation.)
1-3) When the Forced operation is selected, the compressor and the F-Fan operate for 24
hours without stopping and the Fridge compartment will operate according to the set
temperature.
1-4) When the unit is shifted to the Forced Operation, the Freezer and the Fridge temperatures will be set
to -23
℃
and 1
℃
.
1-5) When the Forced Operation is selected, the Power Freeze function won't work.
And, when the Power Freeze function is selected, the Power Freeze LED will go off in 10 seconds.
1-6) When the Forced Operation or the Test function is cancelled within one minute after the Forced
Operation being selected, the set temperature will automatically change to the previously set
temperature.
1-7) The alarm sound during the Forced Operation (0.25 sec On and 0.75 sec Off) keeps on until the
Forced Operation completes and there is no cancellation function.
2. Forced Defrost Function
2-1) When any button is pressed one more time at the Test Mode, the Forced Operation
is to be cancelled immediately and it enters into the F-Defrost Mode.
When it enters into the F-Defrost Mode, 'Fd' will light up on the 7-segment LED.
With the Bar Type Display, the "Mid", "Low-Mid" and "Low" temperature LEDs start
on. And, it indicates that it is in the F-Defrost Mode.
2-2) At this time, it sends out "Beeping" sound for 3 seconds.
This alarm sound repeats 0.75 sec On and 0.25 sec Off which keeps on until the
Forced F-Defrost finishes.
3. Test Cancellation Mode
3-1) When turning the display panel into the Test mode and pressing the TEST button once more during
the Forced F-Defrost, the Forced F-Defrost will be cancelled and it will go back to the normal
operation.
Also, when the unit is plugged out and in again, the Test mode is to be deactivated.
Содержание RL60GG Series
Страница 12: ...12 2 PRODUCT SPECIFICATIONS 592 1201 7 595 500 584 675 712 2010 2 4 Dimensions mm RL60 RL58 RL56 2010 1920 1850...
Страница 75: ...75 5 PCB DIAGRAM 5 3 Connector Layout and Description Main Board 5 3 1 Q G J OPTION...
Страница 76: ...76 5 PCB DIAGRAM 5 3 2 R P Z H Option...
Страница 77: ...77 5 PCB DIAGRAM 5 3 3 L Option...
Страница 78: ...78 5 PCB DIAGRAM 5 3 4 W E Option...
Страница 80: ...80 5 PCB DIAGRAM IPM DIODE VOLTAGE 5 5 IPM Diode Voltage...
Страница 81: ...81 6 WIRING DIAGRAM 6 1 Q G J OPTION...
Страница 82: ...82 6 WIRING DIAGRAM 6 2 R P Z H Option...
Страница 83: ...83 6 WIRING DIAGRAM 6 3 L Option...
Страница 84: ...84 6 WIRING DIAGRAM 6 4 W E Option...
Страница 85: ...85 6 WIRING DIAGRAM 6 5 S Option...
Страница 86: ...86 7 CIRCUIT DIAGRAM 7 1 Schematic Diagram PBA Main 7 1 1 Q G J OPTION...
Страница 87: ...87 7 CIRCUIT DIAGRAM 7 1 2 R P Z H L Option...
Страница 88: ...88 7 CIRCUIT DIAGRAM 7 1 3 W E S Option...
Страница 89: ...89 7 CIRCUIT DIAGRAM 7 2 Schematic Diagram PBA Inverter...
Страница 90: ...90 7 CIRCUIT DIAGRAM 7 3 Block Diagram PBA Main...
Страница 91: ...91 7 CIRCUIT DIAGRAM 7 4 Block Diagram PBA Inverter G H L P R Z Option...
Страница 92: ...92 7 CIRCUIT DIAGRAM 7 5 Block Diagram PBA Inverter Q J Option...
Страница 93: ...93 8 REFERENCE INFORMATION 9 2 Nomenclatrue...