![Sampo Rosenlew Comia c4 Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/sampo-rosenlew/comia-c4/comia-c4_instruction-book_805454075.webp)
– 73 –
Operation / adjustment
There is no separate power switch in the equipment, but it gets switched on when the engine is started. Starting
up takes a while.
The basic factory settings can be adjusted to suit the conditions.
3ODQWW\SHVZLWFKLQWKHORVVVHQVRUV
The loss sensors have a three-position switch by which the basic setting is made. The symbol on the switch
displays three different-size rings: a small one for hayseeds and rape, a medium size one for grain and a big one
for peas and beans. The factory setting is suitable for grain.
Sensor for the amount of returns
In principle the returns sensor is similar to the loss sensor. Its “microphone cover” is thicker to be able to
withstand the abrasion caused by the flow of returns.
The sensors have a three-position switch by which the basic setting is made. The symbol on the switch displays
three different-size rings: a small one for hayseeds and rape, a medium size one for grain and a big one for peas
and beans. The factory setting is suitable for grain.
6HQVLWLYLW\RIWKHORVVGLVSOD\
The sensitivity of the loss display can be adjusted between 0 and 199. 0=less sensitive, 199=the most sensitive.
The sensitivity of shaker shoe losses is set at 100 at the factory and that of straw walker losses at 150. Sensitivity
can be adjusted to suit the conditions.
6HQVLWLYLW\RIWKHGLVSOD\LQGLFDWLQJWKHDPRXQWRIUHWXUQV
The sensitivity of the loss display can be adjusted between 0 and 199. The factory setting is at 30. Sensitivity can
be adjusted to suit the conditions.
Rotation control
Alarm limits have been set on shaft rotation control. These limits can be adjusted if necessary. The fan and
cylinder limits depend on the variator adjustment. An advisable alarm limit is 8-20% below normal speed. Alarm
can be switched off if so required.
Automatic adjustment of the pick-up reel
In the automatic position reel speed should be adjusted either higher or lower than the selected rate of ground
speed. However, the adjustment range sets its own limits. No adjustment is made with the table raised or with the
table stopped.
The adjustment system has limiter switches that stop the servomotor at the end of the adjustment range.
$GMXVWPHQWRIWKHWDEOH´FXWWLQJKHLJKW´
Combines have a potentiometer operating as a height sensor. The cutting height can be set at any height on the
screen or the SA
9
E key can be pressed at the desired height on the encoding screen.
Calculation of the area and the threshing time as well as reel adjustment stop when the ”table up” symbol is
displayed on the screen.
Содержание Comia c4
Страница 2: ......
Страница 16: ... 14 ...
Страница 126: ... 124 C8 C8 C8 LUBRICATION DIAGRAM ...
Страница 134: ... 132 M3 ...
Страница 136: ... 134 M6 ...
Страница 137: ... 135 M7 ...