![Sampo Rosenlew Comia c4 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/sampo-rosenlew/comia-c4/comia-c4_instruction-book_805454006.webp)
– 4 –
A2
A3
EXIT
Never use the combine for anything but threshing.
Manual feeding of crops onto the cutting table is pro-
hibited.
Before starting, particularly reversing, make sure that
everybody nearby is aware of your intentions.
Test the brakes as soon as you start, and stop immedi-
ately if the brakes or steering operate defectively.
Never adjust the seat or steering wheel while driving.
Never leave the cab while the combine is moving.
Never leave the engine running unattended.
Do not open any guards with the engine running.
Do not climb on top of the grain tank or the straw walk-
ers with the engine running, and do not let anybody
else do it either.
Beware of the cutting mechanism and the rotating
chopper knife.
Keep in mind that with the chopper rotating, there is a
20 m no-access danger zone behind the chopper.
Drive carefully on hillsides; the combine may overturn,
particularly with the grain tank full.
The combine cab is no safety cab.
THE RIGHT-HAND SIDE DOOR MAY BE USED AS
AN EMERGENCY EXIT. PULL UP THE HANDLE,
AND OPEN THE WINDOW. Fig. EXIT
Note the recommended safety distances when thresh-
ing under power lines.
Stop the engine before cleaning or servicing the com-
bine.
Stop the combine and the engine immediately if there
is an alarm or any abnormal sounds or smells. Find out
the reason for them, and solve the problem before car-
rying on with threshing.
Support or lock the cutting table and the reel before
going beneath them.
Never clean the combine without proper equipment.
When leaving the combine, lower the cutting table,
lock the parking brake, stop the engine and remove
the ignition key.
SAFETY DISTANCES WHEN THRESHING
UNDER OPEN-WIRE POWER LINES
The minimum clearance between the combine and
power lines with voltage must be in accordance with
the enclosed illustration, in which the danger zone is
darkened.
Low-voltage power lines,
¿
g. A3
240
400
9
can be
distinguished from high-voltage line,
¿
g. A4...A5
over
1 k
9
by the smaller insulators and the fact that there
are usually 4 low-voltage lines.
In case the height or voltage of the power line is dif-
¿
cult to estimate, the Electric Company shall be con-
sulted.