6 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 7
APPENDIX A
SECtION 3 |
Operation
3.2 PoWeR on / PoWeR oFF
Power on
To power ON the EVO
TM
Inverter/Charger, press and hold the
on/oFF
Key continuously for
around 2 sec until competion of sequence explained below:
POWER ON...
SEARCHING ID...
ID= 1
EVO-XXXXE VX.XX
INVERTER/CHARGER
ò
ò
When the EVO
TM
Inverter/Charger is OFF and the
on/oFF
key is
pressed and held, the LCD screen shows “POWER ON…” and
the Status LED flashes 3 times. EVO-RC starts to search for the
communication ID of the EVO
TM
Inverter/Charger it is attached
to. The LCD screen shows “SEARCHING ID” on the first line and
shows the ID number found on the second line.
the on/oFF
Key may be released now
(At this point, around 2 sec would
have elapsed from the time the ON/OFF Key is kept pressed
continuously). When the default ID of “1” is found, the display
will then show the EVO
TM
Inverter/Charger Model No. EVO-
XXXXE and Firmware Version VX.XX.
Power oFF
Press
on/oFF
Key and hold for 5 seconds to turn OFF the EVO
TM
Inverter/Charger.
POWER OFF...
When EVO
TM
Inverter/Charger is ON and the
on/oFF
key is
pressed and held for minimum of 5 seconds, the LCD screen
will show “POWER OFF…” and both the Status and Alarm
LEDs will turn ON. Now release the ON/OFF key (Please note
that Power Off sequence will be completed and display
"POWER OFF..." will disappear only when the ON/OFF key
is released).
note: if the eVo
TM
inverter/Charger has AC input volt-
age over 140 ± 10 VAC available at the Grid / Genera-
tor inputs, the Power oFF function is disabled and the
unit will remain in the on condition if the power off
sequence is attempted. the AC input must be removed
before the unit can be powered oFF.
3.3 DAte AnD tiMe SetUP
Set date and time as per procedure given at Section 4.9: "GROUP 6 PARAMETER SETUP: TIME
SETTING".
3.4 StAnDBY MoDe
When the EVO
TMis
is in Standby Mode, inverting or charging / AC pass through will be suspended.
This Mode is required to be switched ON manually during firmware uploading procedure for
EVO
TM
Inverter/Charger. Firmware upload is carried out through the SD Card slot [9, Fig 1.1(a)].
When firmware uploading procedure is initiated, the user will be prompted to switch ON
Standby Mode – message on the LCD screen will show “Press power key to stop inverter”.
Once firmware upload is completed, the EVO
TM
exits the Standby Mode automatically.
Содержание Evolution Series
Страница 139: ...SAMLEX AMERICA INC 49 APPENDIX A Notes...