76 | SAMLEX AMErICA INC.
SAMLEX AMErICA INC. | 77
note:
Procedure described above is to be used when the optional remote
Control EVO-rC has NOT been plugged into the rJ-45 remote Control
Jack. Please note if the remote Control has been plugged into the rJ-
45 Jack, the above procedure cannot be activated and the ON/Off of
Equalization Mode will be controlled by the remote Control EVO-rC.
using optional remote Control eVo-rC:
Please refer to the attached Owner's
Manual for EVO-rC at Appendix A.
SECTIOn 6 |
Operation, Protections and Troubleshooting
beFore oPerAting the unit, PLeASe enSure thAt the unit hAS been inStALLeD
ProPerLy AS Per inStruCtionS At SeCtion 3 oF thiS MAnuAL.
PLeASe enSure thAt ALL SAFety inStruCtionS At SeCtion 1 oF thiS MAnuAL
Are reAD AnD unDerStooD beFore oPerAting the unit.
inFo
a) Minimum battery voltage required for initiating
manual
switching on of the unit
is as follows:
•
12V units ----- higher than 9V
•
24V units ---- higher than 18V
b) Please note that this unit is designed to Power on AutoMAtiCALLy if (i) AC voltage
of 140 ± 10 VAC is available at the grid / generator input and (ii) DC input voltage is
> 12 VDC for eVo-3012e / 2212e and > 24 VDC for eVo-4024e / 2224e. if the AC input
voltage and frequency are within the programmed limits, the unit will automatically
operate in “Charging Mode”. if the AC input voltage and frequency are not within the
programmed limits, the unit will operate in “Discharging / inverter Mode”. Further, as
long as AC input voltage 140 ± 10 VAC is present, the unit CAnnot be PowereD oFF
using the on / oFF button on the front panel of the unit or on the optional remote
Control eVo-rC (see Appendix A). Switch oFF the AC input first if the unit is required
to be powered off. however, if the unit is in “Fault Mode”, it will be possible to power
oFF the unit with the help of the on/oFF Push button
c) before proceeding, confirm that the unit is not in Standby Mode by pressing on/
oFF button briefly. (Standby Mode is used for Firmware upload through the optional
remote Control eVo-rC (see Appendix A))
o
if LeD marked “on” (12, Fig 2.1) stays oFF, then unit is oFF.
o
if this LeD is on or is flashing, the unit was in Standby Mode and is now on
6.1 Powering on uSing on/oFF button on the Front PAneL
(11, Fig 2.1)
6.1.1 Powering on
To power ON the unit, press and hold the ON/Off button (11, fig 2.1)
for 2 seconds
.
Green LED marked “ON” (12, fig 2.1) will flash 3 times, will go off momentarily and will
then be steady Green. Now, release the ON/Off button. Subsequently, the lighting pat-
tern of this LED will be controlled by various operating conditions given in Table 6.1.
SECTIOn 5 |
Battery Charging in Evolution
TM
Series
Содержание Evolution Series
Страница 139: ...SAMLEX AMERICA INC 49 APPENDIX A Notes...