4 | SAMLEX AMERICA INC.
APPENDIX A
SECtION 2 |
Installation
2.1 inStALLAtion GUiDeLineS
The remote control is provided with 10M/33ft, RJ-45 Data Cable (Straight Wired). Check the
proposed routing distance of the wire and use longer wire, if necessary.
•
Flush mounting of the Remote requires appropriate cut-out in the wall/panel. Take
necessary precautions to ensure any wiring/plumbing running behind the wall/panel is
not damaged.
•
Route the wire to ensure there are no kinks.
•
Use appropriate grommets when the wire is passed through holes in studs/partitions to
prevent damage to insulation.
2.1.2 tools Required
Following tools are recommended:
• Phillips Head Screwdriver • Level
• Hand Drill
• Knife/Saw
• Pencil
• Drill Bit (2.5mm / #39)
Fig 2.1 eVo-RC Remote Cutout Dimensions
2.2 FLUSH MoUnt inStALLAtion
To flush mount, the wall opening must have at least a 2” (5 cm) depth to make room for the
remote and cable. Also, the thickness of wall/panel board at the place of mounting should not
be more than 13 mm to ensure that the RJ-45 jack opening is not obstructed (see Fig. 2.3).
1.
Cut an opening in the wall using the supplied paper template (based on Fig 2.1).
2.
Drill four pilot holes (use 2.5mm diameter/#39 drill bit) for the 4 screws (3mm diameter,
16mm long) that will attach the remote to wall (refer to Figure 2.1 for hole locations and
dimensions).
3.
Route one end of the cable through wall opening to the EVO
TM
Inverter/Charger, and
then plug it into the RJ45 Remote Control Jack port on the EVO
TM
Inverter/Charger.
Содержание Evolution Series