74 | SAMLEX AMERICA INC.
SECTION 4 |
Parameter Setup
4.8.2.7 BUZZER
(Table 4.8, Screen No. 7)
Set the buzzer ON/OFF.
Password 8052
See Section 4.3.1
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P O W E R
S A V I N G
0 = D i s a b l e
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
B U Z Z E R
1 = O n
Down Key x 4 times
Enter Key
Down Key x 6 times
ð
P a s s w o r d
k e y
i n
0 0 0 0
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
B U Z Z E R
1 = O n
Enter Key
4.8.2.8 DISCHARGE BEEP
(Table 4.8, Screen No. 8)
To select the buzzer ON/OFF while in "Inverting Mode".
Password 8052
See Section 4.3.1
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P O W E R
S A V I N G
0 = D i s a b l e
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
D I S C H A R G E
B E E P
0 = O f f
Down Key x 4 times
Enter Key
Down Key x 7 times
ð
P a s s w o r d
k e y
i n
0 0 0 0
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
D I S C H A R G E
B E E P
0 = O f f
Enter Key
4.8.2.9 DEFAULT RESET
(Table 4.8, Screen No. 9)
This is to reset all of the parameters to the Default Values.
Password 8052
See Section 4.3.1
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P O W E R
S A V I N G
0 = D i s a b l e
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
D E F A U L T
P R E S E T
0 = N o
Down Key x 4 times
Enter Key
Down Key x 8 times
ð
P a s s w o r d
k e y
i n
0 0 0 0
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
D E F A U L T
P R E S E T
0 = N o
Enter Key
4.8.2.10 DATALOG TIME AND DATALOG DISABLE
(Table 4.8, Screen No. 10)
Refer to Sections 5.2 to 5.3 on Data Logging. There are 25 Data Fields in Model Nos. EVO-
1212F / 1212F-HW / 1224F / 1224F-HW and 28 Data Fields in Model Nos. EVO-2212 / 3012
/ 2224 / 4024 that can be logged in external SD Card (Refer to Section 5.2.2 and 5.2.3 for
details of the Data Fields). A Real Time Clock inside the EVO-RC-PLUS Remote Control records
Enter Key
See Table 4.8, Screen No. 7
for programmable options
ð
Enter Key
See Table 4.8, Screen No. 8
for programmable options
ð
Enter Key
See Table 4.8, Screen No. 9
for programmable options
ð