76 | SAMLEX AMERICA INC.
SECTION 4 |
Parameter Setup
4.8.2.13 PASSWORD DISABLE
(Table 4.8, Screen No. 13)
In default condition, Password (8052) is required to change the value of programmable pa-
rameter. Use of Password prevents accidental change of parameter setting.
Password may be disabled, if required.
Password 8052
See Section 4.3.1
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P O W E R
S A V I N G
0 = D i s a b l e
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P A S S W O R D D I S A B L E
0 = N o
Down Key x 4 times
Enter Key
Down Key x 12 times
ð
P a s s w o r d
k e y
i n
0 0 0 0
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P A S S W O R D D I S A B L E
0 = N o
Enter Key
4.9 GROUP 6 PARAMETER SETUP: TIME SETTING
Please refer to Parameter "TIME SETTING" under Screen No. 6 for Group 6 at Fig 4.1. Set up de-
tails are given below. The Date and Time Format is Year/Month/Day Hour:Minute (24 hour clock):
NOTE:
Password is not required for setting this parameter.
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
G r o u p
*
T I M E
S E T T I N G
ð
S e l e c t
P a r a m e t e r
T I M E
S E T T I N G
E n t e r
t h e
t i m e
2 0 0 0 / 0 1 / 0 1
0 : 0 0
Down Key x 5 times
Enter Key
i
INFO
•
Time can be programmed from Year 2000 to 2099 only.
•
Month can be programmed from 01 to 12 only.
•
Day can be programmed from 01 to 31 only.
•
Hour can be programmed from 00 to 24 only.
•
Minute can be programmed from 00 to 60 only.
•
If the numbers Entered for Month, Day, Hour and Minute are not within
the above ranges, message "OUT OF RANGE!" will be displayed and the
display screen will go back to the previously set time. Setting procedure
will have to be re-started.
4.10 GROUP 7 PARAMETER SETUP: STOP SD CARD
Please refer to Parameter "STOP SD CARD" under Group 7 at Fig 4.2. Please note that this
set up is displayed / accessible only when SD Card is inserted in the SD Card Slot (9, Fig 1.1a).
Set up details are given below:
Once SD Card is being used, it should be removed/ejected only after the operation of the
Card has been stopped as shown below and message "Please remove SD Card" appears. If
the SD card is not removed within 30 sec, it will reset. After the card is removed, it reverts to
the original operating screen.
Enter Key
See Table 4.8, Screen No. 13
for programmable options
ð
Содержание Evolution Series
Страница 89: ...SAMLEX AMERICA INC 89 Notes...
Страница 90: ...90 SAMLEX AMERICA INC Notes...