Index revision : C - March 2016
30
7105
WARNING : Before any maintenance work on the spray gun, always refer to the health and safety
instructions (
see § 2 page 8
).
- Disconnect the control module from the power supply.
- Check that the air and paint circuits are not pressurised.
- Dump the paint circuit.
10.2. Electropneumatic coupling
•
Step 1
: Remove paint hose. Loosen the paint
hose nut with a 15mm open-ended spanner.
•
Step 2
: Unscrew the fitting nut of the 7/10
polyurethane air hose with an open-ended
spanner of 16.
•
Step 3
: Remove the low voltage cable with a 3mm
allen key, unscrew the two captive screws from
the electropneumatic coupling.
•
Step 4
: Pull the electropneumatic coupling apart
to disconnect.
•
Step 5
: Loosen the air nipple using a 14mm open-ended spanner and replace it.
Step 1
Step 2
Step 3
Step 4
Fitting