Index revision : C - March 2016
14
7105
Low voltage connection fault
: the control module does not detect or any more the
presence of the gun. Switch off the main power supply, check the connection between the
control module and the gun.
High voltage faults
: faults specific to the operation of the gun related to the high voltage:
• Startup of the control module with the engaged trigger.
• Peak of an important over-current during the high voltage.
• Bad functioning of the high voltage unit.
Maintenance indicator light
: This indicator light ignites (orange) from 800000 operations of
the trigger or at the 1000 hours of functioning of the gun (
see § 10.1 page 29
).
The ignition of this light indicates that the maintenance of the gun must be carried out. No
specific maintenance on the GNM 6080.
The control module can manage up to 20 different guns.
12
Plug for gun cable
13
Plug for external cablings
14
Switch ON / OFF
15
Main power supply
16
Ground connection
17
Diaphragm of pressure balancing
18
Diagnosis plug (type mini USB)
Side face of the GNM 6080 control module
12
13
15
14
16
17
18