Index revision : C - March 2016
29
7105
10. Maintenance
10.1. Preventive maintenance table
Carry out when the maintenance indicator light of the GNM 6080 is ON.
WARNING : (*): As soon as one of both terms is reached.
Sub-assembly
Description
Part
number
Qty
Minimum
replacement
frequency
Nozzle support
(JR/JP)
O-ring
J3STKL094
1
3 months
Barrel
Seal cartridge
910014338
1
6 months or 500.000
operations (*)
O-ring (Seal cartridge )
J3STKL005
1
3 months
O-ring chemically inert
J3STKL032
1
6 months
O-ring FEP viton
J2FENV435
1
12 months
O-ring chemically inert
J3STKL078
1
12 months
O-ring chemically inert
J3STKL002
1
12 months
O-ring chemically inert
J3STKL019
1
12 months
Handle
O-ring (electrical connector)
160000041
1
12 months
O-ring (handle base))
160000067
1
12 months
O-ring (air nipple)
J2FTCF018
1
12 months
J3STKL018
1
12 months
Air valve
O-ring - chemically inert (outer of
valve)
J3STKL005
1
12 months
O-ring - chemically inert (inner of
valve)
J3STKL032
1
12 months
Sealing ring
900010256
1
12 months