Index revision : C - March 2016
38
7105
Level 3: If the magnet is broken or lost.
• Replacer the air valve (P/N 910015405) (
see § 10.9 page 36
).
Before using the spray gun, check the activating and the stop of the high voltage.
If the high voltage is permanently activated, disassemble the handle and remove one of the washers
which adjust the position of the sensor reed, proceed step by step, don’t remove several washers at the
same time.
If the high voltage does not start, disassemble the handle and add a washer to adjust the position of the
sensor reed, proceed step by step, don’t add several washers at the same time.
WARNING : Various thicknesses of washers can be in position, begin always to add or remove
the finest.
10.9.1.1. Direction of assembling of the magnet
•
Case Nr 1
: For the guns of the type 1 (see serial number). Rear support without groove, the side
silver plated of the magnet must be in contact with the shoulder of the rear support.
•
Case Nr 2
: For the guns of the type 2 (see serial number). Rear support with grooves, the black
side of the magnet must be in contact with the shoulder of the rear support.
10.10. Fixing hook
• Put the switch in position " I ". With a 5,5mm
screwdriver, unscrew the shouldered screw and
remove the hook by pulling upwards.