Index revision : A
索引版本:A
65
7115
Generator short-circuit:
静电发生器短路:
-
通过外部
- by the air channel
—
通过风道
Clean the air channels in the barrel
清
理枪筒中的风道
Generator short-circuit:
静电发生器短路:
-
通过外部
- by the product hose
—
通过产品软管
Verify product resistivity based on
根据枪型检查产品电阻率
the gun model version
The operator has felt
操作人员触碰部件时察觉
到漏电
electrical discharges
when touching the
part.
Part not grounded or poorly
grounded
部件未接地或接地
不良
Verify the ground connections. The
检查接地接口
联邦快递公司博客
user must wear gloves and
conductive shoes, in accordance
with Standards EN 61340-4-3 and
ISO20344.
用户必须按照
61340-4-3
标准和
ISO20344
的要求
穿戴手套和导电鞋