36
DRT7115
E - 2022/11
Member of EXEL group
6.3.3.
Procedure A3: Hollow cone nozzle cleaning
It is vital to clean the spraying head fully at the end of each shift or when use is interrupted, depending on the
type of product between 5 and 30 minutes.
Cleaning procedure
:
•
Step 1
: Disconnect the air and high voltage
supplies. Engage the safety catch (
A
) on the
trigger.
•
Step 2
: Loosen the cap nut, retrieve the cap
and the low cone and plunge them into a
solvent bath for a few minutes then clean
them with a clean cloth.
•
Step 3
: Using an 11 flat wrench, unscrew the
injector, leave to soak in the solvent then clean
with a clean cloth and a soft brush.
•
Step 4
: Screw the placebo (
B
) injector fully in
place by hand.
Remove the safety catch and dump the circuit.
A
B
Содержание Nanogun+ Airmix
Страница 61: ...61 Member of EXEL group 8 1 Nanogun Airmix guns for both high resistivity HR solvent based paints 1 1 1 2 3 ...
Страница 87: ...87 Member of EXEL group 11 Appendices 11 1 Maintenance preventive plan ...
Страница 92: ...88 DRT7115 E 2022 11 Member of EXEL group 11 2 EU and UK Declarations of conformity ...