12
DRT7115
E - 2022/11
Member of EXEL group
1.7. Installation rules
•
The manual projection electrostatic material must be used only in projection area according to the
standard EN 16985 or in equivalent conditions of ventilation.
• The control module must
not be installed where there is a potential explosion risk
.
• It must be impossible to start up the control module before the spray booth air extraction system is in
operation.
• Connect the control module correctly to the earth terminal of the installation to avoid electromagnetic
interference. The resistance between the module's earth and the installation's earth should be as low
as possible, in the order of a few ohms.
• The paint (or solvent) pump and tank must be connected to a ground terminal on the device.
• All metal parts of the apparatus (paint pumps, containers, stools, turntables, etc.) less than three
metres from the spray gun must be grounded.
• The spraying area must be kept clean and clear of any unnecessary items.
• The floor on which the operator works must be dissipator (bare concrete or metal duckboard). Never
use an insulating floor covering. In area potentially explosive, the assemblies of grounds have to be
dissipators according to the standard EN 61340-4-1.
• Naked flames, glowing objects or a devices likely to produce sparks (other than the atomizer) must not
be used inside the booth.
The storage of inflammable products, or vessels that have contained them, close to the booth or in front
of the doors is prohibited.
• Pots and tubs containing paint or solvent must always be closed after use.
• The paint supply pump used must have a maximum ratio of 1:1 and the pump air supply must be fitted
with a safety valve limiting the pressure to 6.5 bar maximum.
•
In the explosive area,
it is forbidden to use any non-certified electrical or non-electrical equipment
such as electronic extension leads, multiple socket adapters, switches, etc.