Reassembly:
The repair kit includes an electrode equipped
with its small PTFE tube.
•
Step 1
: If necessary, clean the electrode man-
ually and with precaution with a drill or metal
rod of 1mm diameter
•
Step 2
: Insert the electrode equipped with the
PTFE tube. As soon as it appears on the other
side of the air cap, pull it with fingers. Then
push it to the bottom of the housing with the
screwdriver, the return strand of the electrode
must fit into a small bore, only the rear part of
the electrode must flush with the bottom of
the counterbore.
•
Step 3
: Clip the PTFE conductive washer.
Replace it if necessary. It is advised not to
reuse it more of 3 or 4 times, the washer
should not be able to be removed without the
use of a tool.
•
Step 4
: Check the continuity between the
conductive PTFE washer and the metal end of
the electrode. The usually measured value is
of the order of 200 to 300
Ω
but a value up to
1000
Ω
is admissible.