20
DRT7115
E - 2022/11
Member of EXEL group
Low voltage connection fault
:
•
The control module does not detect or any more the presence of the gun.
Switch off the main power supply, check the connection between the control module and the gun.
• This fault may also be related to electromagnetic interference generated by other equipment in
the installation.
•
Check that the module is earthed and that the other equipment complies with electromagnetic
compatibility rules.
Nota:
One or more alarm lights come on at random and sometimes it is impossible to acknowledge
them, and/or the red and blue LED strips do anything when the trigger is pulled and/or nothing
happens when the trigger is pulled.
Remedies:
Turn off the GNM and turn it back on 2 or 3 seconds later, this can be repeated 2, 3 or 4 times if
it doesn't work. If it still doesn't work: Check the electronic disturbance in the vicinity of the module
and the ground of the building to which the module is connected.
High voltage faults
:
faults specific to the operation of the gun related to the high voltage:
•
Start up of the control module with the engaged trigger.
• Peak of an important over-current during the high voltage.
•
Bad functioning of the high voltage unit.
Maintenance indicator light:
This indicator light ignites (orange) from 800000 operations of the
trigger or at the 1000 hours of functioning of the gun (
The ignition of this light indicates that the maintenance of the gun must be carried out. No specific
maintenance on the GNM 6080.
If one or more lights or barographs come on at random, after switching off the power supply to
the module,
it is necessary to check that the module is earthed and that other equipment complies with
electromagnetic compatibility regulations.
Содержание Nanogun+ Airmix
Страница 61: ...61 Member of EXEL group 8 1 Nanogun Airmix guns for both high resistivity HR solvent based paints 1 1 1 2 3 ...
Страница 87: ...87 Member of EXEL group 11 Appendices 11 1 Maintenance preventive plan ...
Страница 92: ...88 DRT7115 E 2022 11 Member of EXEL group 11 2 EU and UK Declarations of conformity ...