23
Member of EXEL group
Measurement conditions:
The apparatus was operated to maximum capacity and the measurements taken in the manual paint test
booth (sealed booth with glass panels) located in the
Sames
site in Meylan, France.
Measurement method:
The weighted equivalent sound pressure level (93.8 et 98.6 dBA) is an LEQ value measured during
observation periods over at least 30 seconds.
3.2. Flows
3.2.1. Versions without whip (LR)
Flat spray:
Nota: The flow rate measurements were conducted with water.The width of the impact is measured
at a distance of 25 cm (10 inches).
Gauge
Flow rate (in cc/min)
Width, in cm
at 70 bar
at 120 bar
at 200 bar
03-05
150
200
260
12
03-07
150
200
260
17
04-05
220
290
380
12
04-07
220
290
380
17
04-09
220
290
380
21
04-11
220
290
380
25
04-13
220
290
380
29
06-09
330
430
570
21
06-11
330
430
570
25
06-13
330
430
570
29
06-15
330
430
570
33
09-09
450
590
770
21
09-11
450
590
770
25
09-13
450
590
770
29
09-15
450
590
770
33
12-11
600
790
1030
25
12-13
600
790
1030
29
12-15
600
790
1030
33
14-09
720
940
1230
21
14-11
720
940
1230
25
14-13
720
940
1230
29
14-15
720
940
1230
33
14-17
720
940
1230
37
Содержание Nanogun+ Airmix
Страница 61: ...61 Member of EXEL group 8 1 Nanogun Airmix guns for both high resistivity HR solvent based paints 1 1 1 2 3 ...
Страница 87: ...87 Member of EXEL group 11 Appendices 11 1 Maintenance preventive plan ...
Страница 92: ...88 DRT7115 E 2022 11 Member of EXEL group 11 2 EU and UK Declarations of conformity ...