232
•
Appendix
Sam4POS 6600/4800II Operators Manual v2.9
Vx805 Out Of Memory
The VX805 Pin-Pad at times displays an “Out of Memory” error message. After rebooting a couple of
times the “Out of Memory” instruction is sent, and the error is resolved with the rebooting of the Pin-
Pads. After some time, the VX805 may start to display the “Out of Memory” error message again.
Please
carefully
follow the “Out of Memory” instructions below prior to further troubleshooting.
Some PIN pads loaded with XPI 8.42b/8.43c may be shipped from distributors missing 2 parameters
required for reliable operation. Follow the steps below to set these parameters manually from the PIN
pad’s system menu.
1.
Press
F2
and
F4
to enter system mode.
2.
The password is:
1 ALPHA ALPHA 6 6 8 3 1
; Press
ENTER
(Alpha is a black key located directly
above the 2 key Enter is the Green key)
3.
Press
2
for
“Edit Parameters”
; Press
ENTER
4.
Select
1
for
“Group ID”
. The password is:
1 ALPHA ALPHA 6 6 8 3 1
; Press
ENTER
.
5.
Press
ENTER
to select
“CONFIG.SYS”
.
6.
Press
1
for
“New”
.
7.
For the parameter name, enter
*DHEAP
. For the alpha characters, press the associated number key
followed by ALPHA until the correct letter appears. * is located below the 7 key.
8.
Press
ENTER
to confirm the new parameter.
9.
For the value, enter
0
.
10.
Press
ENTER
to confirm the new value.
11.
Press
1
for
“New”
again.
12.
For the parameter name, enter
#CZE
. For the alpha characters, press the associated number key
followed by ALPHA until the correct letter appears. # is located below the 9 key.
13.
Press
ENTER
to confirm the new parameter.
14.
For the value, enter
1
.
15.
Press
ENTER
to confirm the new value.
16.
Press
CANCEL
.
17.
Press
1
for