Faults and fault rectification
Check any faults in the appliance against the following table:
Fault
Possible cause
Action
The green indicator
light does not illumi
nate when switched
on.
Main switch before appliance
not turned on.
Turn on main switch.
There is no power supply at
all.
Inform the power supply company.
Mains fuse has tripped.
Possible faults on the appliance must
be checked by an authorised Customer
Service agent.
Reset the circuit breaker.
The appliance does
not heat up and the
yellow indicator light
is off.
The safety temperature limiter
has tripped.
Check to make sure that the tank is
sufficiently filled with deep-frying oil/fat.
Allow the appliance to cool.
WARNING! Fire danger!
Do not switch
the safety temperature limiter back on
until the cause of the failure has been
rectified.
Push in the switch knob. Contact the
authorized Customer Service if the
fault recurs.
Switch knob for the safety temperature
limiter
If you cannot remedy the fault,
‒ switch off the appliance and disconnect from the mains,
‒ do not open the housing,
‒ contact the authorised Customer Service agent.