![Salvis ProfiLine PLGGH Series Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/salvis/profiline-plggh-series/profiline-plggh-series_operating-instructions-manual_804161041.webp)
en
41 / 44
10.3
Feed combustion air, extract exhaust gases
● The appliance conforms to the gas device type A1. This permits free installation in the room,
without direct connection to an exhaust gas system.
● Observe the country-specific specifications for the supply of combustion air and exhaust gas
extraction!
● The gas fitter calculates the supply of combustion air and exhaust gas extraction required.
Quantity of air required
Per m
3
Natural gas --> approx. 10 m
3
air
Per kg liquid gas --> approx. 12 m
3
air
For gas consumption values, read operating instructions for Gas oven / Gas hob 800
● We recommend to install the appliance below an exhaust air hood. The filters must withstand an
exhaust gas temperature of 300°C. Use a flame protection filter! Maintain a minimum distance of
a metre to the exhaust gas hood!
10.4
Connect gas supply, check the gas connection pressure
Remove front panel
Front panels must only be removed by authorized
customer service or gas fitter!
.
Undo threaded pin and pull off lever.
.
Release the screws below the front panel.
● The number of screws depends on the length
of the appliance.
.
Remove the top screws.
Connect gas supply
.
Do not route the gas supply line along hot sur
faces or sharp edges.
.
Connect gas supply.
.
Integrate the appliance into the equipotential
bonding system.
.
Check all gas-bearing parts for tightness (leak
spray).
Remove the
screws
Undo screws
Lever
Threaded pin
Clamping cam (gas regulator)
Washer
Gas connection
Gas supply line on the baking oven