![Salvis ProfiLine PLGGH Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/salvis/profiline-plggh-series/profiline-plggh-series_operating-instructions-manual_804161033.webp)
en
33 / 44
6.3
Clean stainless steel surfaces
.
Clean stainless steel surfaces with a grease-dissolving cleaning agent.
.
Rinse off cleaned parts thoroughly with water after using harsh cleaning products.
.
Clean stainless steel surfaces with grease-dissolving cleaner or a special stainless steel cleaner.
.
Dry cleaned parts and surfaces with a soft cloth.
● Leave the oven door open after cleaning.
7.
Errors and remedies
If faults should occur on the gas hob, check them using the following table:
Fault
Cause
Remedy
The pilot light does not
light.
Gas tap is closed
Open the gas tap.
On-site gas tap is closed
Open the on-site gas tap.
Thermocouple contaminated
Clean the thermocouple.
The pilot light goes out af
ter the gas control is re
leased.
The gas control was not
pressed in for a long enough
period.
Press gas control for approx.
5 - 10 seconds so that the
thermocouple is sufficiently
heated and the gas supply is
not interrupted.
Pilot burner dirty
Clean pilot burner.
Thermal element defective.
Contact customer service.
Safety temperature limiter has
activated.
Contact customer service.
If the fault cannot be rectified:
.
Press the gas control and turn to "Off" (Symbol●).
.
Close the gas tap on the appliance.
.
Close the gas tap on site.
.
Do not open the housing.
.