40
18.4.
Solar Application scheme D
Loading of DHW reservoir from a solar panel and transfer of accumulated heat to the reservoir
B
.
Fig. 18.4 Application scheme D
Installation notes
1.
This scheme requires two additional CT6 sensors.
2.
Circulation pump is connected to
H
output through a relay with contact current not lower than the
current of the circulation pump. It is recommended to use relays with two switching tracks, see
details in section 17.2.5 Output H.
Setting notes
1.
Do not set
HP2
value higher or equal to
dTAB
, because this will prevent loading stop when
dTAB
value is reached.
2.
With respect to
night cooling mode
used for the reservoir
A
and circulation activation for better
discharge of the container, it is recommended that circulation circuit is installed in the reservoir
A
.