11
Fig. 8.4 Setting edition marker
When you set temperature and pressed
the knob, both edition marker and position
marker will be displayed on the screen, and you
may turn the knob to copy the value to adjacent
positions. Press again the knob to move to the
position marker.
Fig. 8.5 Setting value movement
Select OK and press the knob, while in position
marker mode, to confirm changes made in
schedules. Activate CANCEL to exit without
saving changes in schedules.
8.2.
Circulation
Access
Item available only in schemes B, C, D,
E, G, H, J, K, L
Changes in circulation time programs are
introduced the same like it was demonstrated for
TDHWmin
schedule settings.
Fig. 8.6 Menu structure
Possible settings in value edit box are
YES
,
NO
AND
sch.
Value
YES
will enable
constant circulation. Value
NO
will disable
circulation. Value
sch.
will activate time program
for circulation.
9.
MENU ALARMS
Access
The controller may alarm on any
irregularities in operation.
The controller has an intelligent alarm
function. It means that the controller recognizes
type of alarm condition and takes respective
remedy actions accordingly to the conditions. For
instance, if the sensor of reservoir extra heating
with a heater fails, the controller prevents extra
heating for the reservoir. Despite of alarm, the
solar circuit will continue correct operation and
the controller will not let the reservoir to be
overheated.
Type of action taken by the smart alarm
depends on the alarm type and on the solar
application.
When in the main screen in the screen
bottom ALARM! sign starts blinking (Fig. 5.2), it
means alarm situation. Now, entering through
menu to Alarms we have access to contents and
code number
of alarm reported by the
controller (Fig. below).
Edition marker
Current marker
hour range