Change during operation: N = impossible,
Y* = possible (enabled by using ), Y= possible (enabled by using
)
-47-
FUNC
DATA
Gain
(for frequency setting signal)
This function outputs the frequency obtained by multiplying the reference frequency by a ratio.
This function selects an analog input signal level with a value from 1 to
4 that is set by function F 0 1 .
0 The maximum frequency is output at +10Vdc (20mA dc).
1 The maximum frequency is output at +5Vdc (12mAdc).
When this function is used with function F 1 8 (bias frequency ), the gain set with this function is
valid and the gained frequency is biased.
Bias frequency
This function outputs a frequency biased for the analog frequency setting.
-1
2
0
to
1
2
0
Factory
setting
Change during
operation
0
N
-120 to 120Hz can be set with a resolution of 1Hz.
Factory
setting
Change during
operation
0
Y
0%
Bias (negative)
0
4
+10Vdc
20mAdc
100%
Frequency set-
ting
Bias (positive)
F17
100%
Frequency
setting
+10Vdc
+5
0
20mAdc
12
4
1
0
F18