E -
RICERCA GUASTI
FAULT-FINDING PROCEDURE
CAUTION : if the mains voltage is too low, a safety mechanism prevents the set from being used.
The safety mechanism will be released automatically when the main voltage has returned to normal (220V -
10 %).
Normal cycle
Problem
Probable cause
Checks
Power on
Power on indicator lit
Indicator off
Indicator faulty
Mains supply
ON/OFF switch
If the fan is rotating,
indicator faulty
Check the mains supply
and the mains lead
Check
Fan rotates
Fan does not rotate
Fan faulty
Fuse defective
Check
Check
Green
indicator lit
Green indicator off
Indicator faulty
Thermal safety circuit
broken
Aux. transformer TA1
Control board
Check
Unplug the set and use
an ohmmeter to check
that R
≈
0 between 3
and 4 on B2 on the
control board
Measure :
18V ~ between 2 & 1 on
B3
18V ~ between 2 & 3 on
B3
Measure
+ 15V between 10 & 11
on B5
— 15V between 9 & 10
on B5
No load on set
Voltage nul
Poor contact
Aux. transformer TA1
Check connections on
the different connectors
Measure :
18V ~ between 2 & 1 on
B3
18V ~ between 2 & 3 on
B3
Standby voltage :
Control board
Measure :
2
This indicator light shows that the set is ready to be used. It will go off if the set heats up to too high a
temperature. The set can only be used again once the temperature has returned to normal (when the
indicator light will come on again).
E
-25
PRESTOPAC
160
Содержание PRESTOPAC 160
Страница 2: ......
Страница 4: ......
Страница 9: ...C MESSA IN SERVIZIO STARTING UP AND SERVICING C 15 PRESTOPAC 160 ...
Страница 15: ...D MANUTENZIONE MAINTENANCE Viste esplose Layout of components PRESTOPAC 160 AD 20 ...
Страница 22: ...SCHÉMA ÉLETTRICO ELECTRICAL DIAGRAM E 28 PRESTOPAC 160 ...