I N S TA L L AT I O N I N S T R U C T I O N S
R I V E R R U N S L I D E
13
SBK-RR INSTALL | 0419
Copyright ® 2019 S.R.Smith, LLC All rights reserved. |
srsmith.com
I N S T A L L A T I O N I N S T R U C T I O N S
R I V E R R U N S L I D E
STEP 8: FINAL SLIDE POSITION
It is essential that the slide be in its correct horizontal and vertical position prior to pouring concrete; and since
the pool cannot be moved, start checking position with the exit section first. Starting with and then ensuring that
the exit section is installed correctly is absolutely necessary for a successful installation.
The exit section must meet the pool edge at the correct elevation, in the correct orientation and be level in both
axes. (Fig. 16 & Fig. 17) When determining level position for the exit section please note that the exit section
starts with a 20° up slope, which then makes a gradual transition to 7˚ the exit point. Check for level position only
as illustrated below.
Utilize an angle finder along the centerline of the flume ensure the flume is at the correct angle. Check the angle
along the centerline of the flume only. (Fig. 18)
(Continued on next page)
FIG. 18
FIG. 16
FIG. 17
EXIT IS 7˚ WHEN
CORRECT.