Spiral
®
SST and STT Prewire Installation Manual
Spiral
®
SST and STT Prewire Installation Manual
■
1072124-0
■
Rev 03
■
01/22
31
What to test after powering up the door
Press and hold
the arrows to fully open,
then fully close the door five (5) times.
1
Does the door panel move in the right direction?
Test:
The direction of the door should match the direction of the arrow on the controller.
Yes:
no action is needed.
No:
follow the steps in
How to reverse the rotation of the motor
.
2
Is the door panel level and plumb?
Test:
laser the door along the seal
between two door panel slats.
Yes:
no action is needed.
Panel is not level:
follow the steps in
How to adjust the secondary drive belt
.
Panel is not plumb:
contact Rytec technical support at
800-628-1909
.
3
Are the drive belt pulley assemblies level?
Test:
make sure the secondary drive belts in
both side columns are centered in the
pulley assemblies after the door has been
opened and closed several times.
Yes:
no action is needed.
No:
follow the steps in
How to level the baseplate pulley assembly
.
4
Is the manual brake release operating correctly?
Test:
pull down the lever to 90° to manually release the brake, then push the lever back up to reset it.
Release operating correctly:
when the lever is down, the door panel moves freely and the controller
displays an
F211 Emergency Stop
error. When the handle is reset, the controller displays
Door is Stopped
and you can close the door by pressing the DOWN arrow.
No action is needed.
Release NOT operating correctly:
the
F211 Emergency Stop
error stays on when the lever is reset, and
the door cannot be closed.
Follow the steps in
How to adjust the proximity sensor.
5
Is the door operating correctly?
Test:
listen for grinding, whining or excessive motor noise. Watch for changes in speed or excessive
movement of the motor or drum
Yes:
no action is needed.
No:
contact Rytec technical support at
800-628-1909
.
_0 Hold Reset
!
To Open Pos.
RY-FT-000092
fully open and close door five times
Laser level
Use
the hinge screws
as the vertical reference.
How to reverse the rotation of the motor
First: set the controller to Parameter mode and access Service level parameters
Do This
Result
1
You are in Parameter mode. Go to parameter P:999.
2
The parameter P:999 screen displays.
3
You can now change the value of parameter P:999.
Do This
Result
4
Set the value to 10 (Service level password).
5
The Service level password is saved.
6
You can now go to parameter P:130.
Next: navigate to parameter P:130 and change the value
Do This
Result
1
Value is either 0 or 1.
2
The value is either 1 or 0.
Do This
Result
3
Chage the 0 to 1, or change the 1 to 0.
4
The new value is saved.
5
Reset the limits for the door.
001=
[xxx] Cyc
P:Password
O
until the parameter screen displays
RY-UI-000050
PDN-UI-000051
999=
0000
0
#
00
P:Password
O
2x
to reach parameter P:999
PDN-UI-000052
1x
to move cursor to the right (edit value)
0000
0
#
00
999=
P:Password
O
PDN-UI-000059
999=
0010?#
00
P:Password
O
16x
to set value to hexadecimal 10
PDN-UI-000060
until question mark changes to
checkmark (value saved)
999=
0010
0
#
00
P:Password
S
PDN-UI-000061
1x
to move cursor to left (parameters)
999=
0010
0
#
00
P:Password
S
PDN-UI-000057
130=
0
#
P:Mtr
Rotation S
until parameter displays
PDN-UI-000052
1x
to move cursor to the right (edit value)
130=
0
#
P:Mtr
Rotation S
PDN-UI-000059
press either arrow to change value
130=
1?#
P:Mtr
Rotation S
PDN-UI-000060
130=
1
#
P:Mtr
Rotation S
PDN-UI-000060
_0 Hold Reset
!
To Open Pos.
until the “To Open Pos.” screen displays